Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Braz. j. med. biol. res ; 56: e12781, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520480

ABSTRACT

Treatments that attenuate the effects of hypoestrogenism in menopausal women have been gaining visibility. This study investigated the skin response to a phytoestrogen-enriched cosmetic formulation created by incorporating a biotransformed soybean extract (BE) into a cream-like matrix. Collagen-I expression was analyzed both in vitro (fibroblast cells) and ex vivo (skin explants). The results revealed an increased amount of collagen-I both in fibroblasts and human skin when treated with BE and BE-incorporated cream. Also, this collagen-I overexpression was inhibited by PHTPP, indicating a dependence on estrogen hormone receptor beta (ERβ) signaling. Moreover, BE was not harmful to skin microbiota, showing a promising nutricosmetic potential. Thus, this work presented a fully functional cream-like formulation that was shown to be safe and effectively increase collagen-I levels both in vitro and ex vivo.

2.
Braz. j. biol ; 82: e234471, 2022. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1153460

ABSTRACT

High doses of antibiotics used in hospitals can affect the microbial composition of sewers, selecting resistant bacteria. In this sense, we evaluated the antibiotic resistance profile and the multiresistant phenotype of bacteria isolated in sewage from a tertiary hospital in the interior São Paulo state, Brazil. For bacteria isolation, 10 µL of sewage samples were sown in selective culture media and the isolates were identified using VITEK-2 automatized system. The antibiotic sensitivity test was performed by disk diffusion. High percentages of resistance were found for amoxicillin, ampicillin, ceftazidime, clindamycin, vancomycin and the multidrug-resistant phenotype (MDR) was attributed to 60.7% of the isolates. Our results show bacteria classified as critical/high priority by WHO List of Priority Pathogens (Enterococcus and Staphylococcus aureus resistant to vancomycin and Enterobacteriaceae resistant to carbapenems) in hospital sewage. Therefore, the implementation of disinfection technologies for hospital sewage would reduce the bacterial load in the sewage that will reach urban wastewater treatment plants, minimizing superficial water contamination and bacterial resistance spread in the environment.


Altas doses de antibióticos utilizados em hospitais podem afetar a composição microbiana dos esgotos, selecionando bactérias resistentes. Nesse sentido, avaliamos o perfil de resistência a antibióticos e o fenótipo multirresistente de bactérias isoladas em esgoto de um hospital terciário no interior do estado de São Paulo, Brasil. Para o isolamento de bactérias, foram semeados 10 µL das amostras de esgoto em meios de cultura seletivos e os isolados foram identificados usando o sistema automatizado VITEK-2. O teste de sensibilidade aos antibióticos foi realizado por disco-difusão em ágar. Elevadas porcentagens de resistência foram encontradas para amoxicilina, ampicilina, ceftazidima, clindamicina, vancomicina e o fenótipo multirresistente (MDR) foi atribuído a 60,7% dos isolados. Nossos resultados mostram bactérias classificadas como prioridade crítica/alta pela Lista de Patógenos Prioritários da OMS (Enterococcus e Staphylococcus aureus resistentes à vancomicina e Enterobacteriaceae resistentes aos carbapenêmicos) no esgoto hospitalar. Sendo assim, implementação de tecnologias de desinfecção do esgoto hospitalar reduziriam a carga bacteriana no esgoto que chegará às estações de tratamento de esgoto urbanas, minimizando a contaminação dos ecossistemas hídricos receptores e a disseminação da resistência bacteriana no ambiente.


Subject(s)
Sewage , Bacteria/genetics , Phenotype , Brazil , Microbial Sensitivity Tests , Tertiary Care Centers
3.
Braz. j. biol ; 82: 1-6, 2022. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1468419

ABSTRACT

High doses of antibiotics used in hospitals can affect the microbial composition of sewers, selecting resistant bacteria. In this sense, we evaluated the antibiotic resistance profile and the multiresistant phenotype of bacteria isolated in sewage from a tertiary hospital in the interior São Paulo state, Brazil. For bacteria isolation, 10 µL of sewage samples were sown in selective culture media and the isolates were identified using VITEK-2 automatized system. The antibiotic sensitivity test was performed by disk diffusion. High percentages of resistance were found for amoxicillin, ampicillin, ceftazidime, clindamycin, vancomycin and the multidrug-resistant phenotype (MDR) was attributed to 60.7% of the isolates. Our results show bacteria classified as critical/high priority by WHO List of Priority Pathogens (Enterococcus and Staphylococcus aureus resistant to vancomycin and Enterobacteriaceae resistant to carbapenems) in hospital sewage. Therefore, the implementation of disinfection technologies for hospital sewage would reduce the bacterial load in the sewage that will reach urban wastewater treatment plants, minimizing superficial water contamination and bacterial resistance spread in the environment.


Altas doses de antibióticos utilizados em hospitais podem afetar a composição microbiana dos esgotos, selecionando bactérias resistentes. Nesse sentido, avaliamos o perfil de resistência a antibióticos e o fenótipo multirresistente de bactérias isoladas em esgoto de um hospital terciário no interior do estado de São Paulo, Brasil. Para o isolamento de bactérias, foram semeados 10 µL das amostras de esgoto em meios de cultura seletivos e os isolados foram identificados usando o sistema automatizado VITEK-2. O teste de sensibilidade aos antibióticos foi realizado por disco-difusão em ágar. Elevadas porcentagens de resistência foram encontradas para amoxicilina, ampicilina, ceftazidima, clindamicina, vancomicina e o fenótipo multirresistente (MDR) foi atribuído a 60,7% dos isolados. Nossos resultados mostram bactérias classificadas como prioridade crítica/alta pela Lista de Patógenos Prioritários da OMS (Enterococcus e Staphylococcus aureus resistentes à vancomicina e Enterobacteriaceae resistentes aos carbapenêmicos) no esgoto hospitalar. Sendo assim, implementação de tecnologias de desinfecção do esgoto hospitalar reduziriam a carga bacteriana no esgoto que chegará às estações de tratamento de esgoto urbanas, minimizando a contaminação dos ecossistemas hídricos receptores e a disseminação da resistência bacteriana no ambiente.


Subject(s)
Enterococcus/pathogenicity , Sewage/analysis , Water Microbiology/standards , Water Pollutants, Chemical/analysis , Water Pollutants, Chemical/toxicity , Drug Resistance, Microbial , Staphylococcus aureus/pathogenicity
4.
Braz. j. biol ; 822022.
Article in English | LILACS-Express | LILACS, VETINDEX | ID: biblio-1468606

ABSTRACT

Abstract High doses of antibiotics used in hospitals can affect the microbial composition of sewers, selecting resistant bacteria. In this sense, we evaluated the antibiotic resistance profile and the multiresistant phenotype of bacteria isolated in sewage from a tertiary hospital in the interior São Paulo state, Brazil. For bacteria isolation, 10 µL of sewage samples were sown in selective culture media and the isolates were identified using VITEK-2 automatized system. The antibiotic sensitivity test was performed by disk diffusion. High percentages of resistance were found for amoxicillin, ampicillin, ceftazidime, clindamycin, vancomycin and the multidrug-resistant phenotype (MDR) was attributed to 60.7% of the isolates. Our results show bacteria classified as critical/high priority by WHO List of Priority Pathogens (Enterococcus and Staphylococcus aureus resistant to vancomycin and Enterobacteriaceae resistant to carbapenems) in hospital sewage. Therefore, the implementation of disinfection technologies for hospital sewage would reduce the bacterial load in the sewage that will reach urban wastewater treatment plants, minimizing superficial water contamination and bacterial resistance spread in the environment.


Resumo Altas doses de antibióticos utilizados em hospitais podem afetar a composição microbiana dos esgotos, selecionando bactérias resistentes. Nesse sentido, avaliamos o perfil de resistência a antibióticos e o fenótipo multirresistente de bactérias isoladas em esgoto de um hospital terciário no interior do estado de São Paulo, Brasil. Para o isolamento de bactérias, foram semeados 10 µL das amostras de esgoto em meios de cultura seletivos e os isolados foram identificados usando o sistema automatizado VITEK-2. O teste de sensibilidade aos antibióticos foi realizado por disco-difusão em ágar. Elevadas porcentagens de resistência foram encontradas para amoxicilina, ampicilina, ceftazidima, clindamicina, vancomicina e o fenótipo multirresistente (MDR) foi atribuído a 60,7% dos isolados. Nossos resultados mostram bactérias classificadas como prioridade crítica/alta pela Lista de Patógenos Prioritários da OMS (Enterococcus e Staphylococcus aureus resistentes à vancomicina e Enterobacteriaceae resistentes aos carbapenêmicos) no esgoto hospitalar. Sendo assim, implementação de tecnologias de desinfecção do esgoto hospitalar reduziriam a carga bacteriana no esgoto que chegará às estações de tratamento de esgoto urbanas, minimizando a contaminação dos ecossistemas hídricos receptores e a disseminação da resistência bacteriana no ambiente.

SELECTION OF CITATIONS
SEARCH DETAIL